Features
Specifications
Product Name: Plasma Consumables
Application: Plasma Cutting Machine
Standard: Manufacturer Production Standard
Type: .11.848.221.407 G2007Y
High Light:

plasma cutting machine parts

,

powermax 1650 parts

Basic Infomation
Place of Origin: China
Brand Name: Plasma Consumables
Certification: ROHS/ SGS
Model Number: .11.848.221.407 G2007Y
Payment & Shipping Terms
Packaging Details: Manufacturer packing
Delivery Time: Prompt goods
Payment Terms: T/T or western Union
Supply Ability: 10,000pcs per month
Product Description

.11.848.221.407 G2007Y For Kjellberg Plasma Cutter Machine Nozzle

 

We can offer you all plasma consumables for , Kjellberg, Esab, Koike, Komatsu, Thermadyne, such as: electrode, nozzle, shield, swirl ring, inner cap, retaining cap, water tube, torch body and so on.

Customer Satisfaction

If you worry about our products’ quality, I can give you some samples to test by free. Please don't hesitate to contact us if you have any questions or concerns before or after your purchase. We are committed to your 100% satisfaction.

Shipping and handing

1. DHL is our preferred shipping method. Meanwhile TNT, EMS, Fedex, UPS are available.
2. Make sure to leave telephone number when filling your buyer information.
3.You can check the goods where it is in transit through tracking NO .

Refund(Echange Only)

1.If you are not satisfied with your purchase, you can echange the items received. you must contact us within 5 days of the receipt

of your order. And you should pay all additional shipping fees incurred and the items returned should be kept in their original

status.

2.If you wish to echange defective or incorrect shipped goods, please contact us within 5 days after receiving the goods.

Notes

1. The buyer are responsible for any insurance you think necessary.

2. The processing time for a specific order varies with the product type and stock status. Mostly, processing time can be 3 to 15 working days.

 

 

Machine HEC NO. Thum NO. Ref NO. Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hifocus 280i

Hifocus 360i

Hifocus 440i

(Carbon Steel)

K94211 G901Y .11.848.201.142 Cooling tube
K94212 G902Y .11.852.201.142 Cooling tube
K94241 G931Y .11.848.401.142 Cooling tube
K0402 G002Y .11.848.221.300 Cathode O2
K0105 G015Y .11.848.231.350 Cathode O2
K0101 G011Y .11.848.231.320 Cathode O2
K0106 G016Y .11.848.231.360 Cathode O2
K0402 G092Y .11.848.401.310 Cathode O2
K7441 G101 .11.848.221.145 Gas guide
K1466 G2006 .11.848.221.406 Nozzle O2 25A
K1467 G2007 .11.848.221.407 Nozzle O2 35A
K54124 G3004 .11.848.201.1604 Nozzle cap
K641515 G4015 .11.848.201.1515 Swirl gas cap
K641220 G4020 .11.848.201.1520 Swirl gas cap
K44191 G501 .11.848.201.081 Protective cap
K0403 G003Y .11.848.221.310 Gathode -O2
K7442 G102 .11.848.221.146 Gas guide
K1466 G2006Y .11.848.221.406 Nozzle O2
K1467 G2007Y .11.848.221.407 Nozzle O2
K1468 G2008Y .11.848.221.408 Nozzle O2 50A
K14610 G2010Y .11.848.221.410 Nozzle O2 80A
K14612 G2012Y .11.848.221.412 Nozzle O2 120A
K14614 G2014Y .11.848.221.414 Nozzle O2 160A
K14616 G2016Y .11.848.221.416 Nozzle O2 200A
K14826 G2326Y .11.848.221.426 Nozzle
K14830 G2330Y .11.848.221.430 Nozzle
K14831 G2331Y .11.848.221.431 Nozzle
K11014 G2514 .11.848.311.614 Nozzle
K11015 G2515 .11.848.311.615 Nozzle
K11016 G2516 .11.848.311.616 Nozzle
K11018 G2518 .11.848.311.618 Nozzle
K11125 G2725 .11.848.411.625 Nozzle
K11127 G2727 .11.848.411.627 Nozzle
K11129 G2729 .11.848.411.629 Nozzle
K541228 G3028 .11.848.201.1628 Nozzle cap
K641522 G4022 .11.848.201.1522 Swirl gas cap
K641525 G4025 .11.848.201.1525 Swirl gas cap
K641530 G4030 .11.848.201.1530 Swirl gas cap
K04242 G032Y .11.848.421.310 Cathode O2
K04244 G034Y .11.848.421.330 Cathode O2
K74251 G121 .11.848.421.145 Gas guide
K14826 G2326Y .11.848.421.426 Nozzle O2 280A
K14830 G2330Y .11.848.421.430 Nozzle O2 360A
K14831 G2331Y .11.848.421.431 Nozzle -O2-400A
K541409 G3209 .11.848.401.1609 Nozzle cap
K541419 G3219 .11.848.401.1619 Nozzle cap
K541429 G3229 .11.848.401.1629 Nozzle cap
K641745 G4345 .11.848.401.1545 Swirl gas cap
K641750 G4350 .11.848.401.1550 Swirl gas cap
K641755 G4355 .11.848.401.1555 Swirl gas cap
K44201 G521 .11.848.401.081 Protective cap
K94211 G901Y .11.848.201.142 Water Tube
K94212 G902Y .11.852.201.142 Water Tube
K94241 G931Y .11.848.401.142 Water Tube


 
Technical Support:

Anti interference wiring measures for machine tools

 

CNC device and servo unit of NC plasma arc cutting system is the core part of the system, the power supply is the main way to enter the interference. The interference of power supply is mainly produced by the impedance coupling power supply line, all kinds of high-power electric equipment is the main source of interference.

 

3.1 power supply into line with shielded wire

 

Power line NC plasma arc cutting system. Cathode line of the cutting torch and plasma / arc arc line hanging in the sliding support, equivalent to go parallel lines tens of meters and / arc line control, torch cathode line from the plasma power, torch cathode of the DC line current 100 amperes. It produces electromagnetic field and high frequency lead arc of high frequency signal by coupling the will power of CNC device and servo unit caused by electromagnetic interference.

 

With copper and aluminum for shielding cable shielding layer can effectively suppress the interference of high frequency electromagnetic shielding, grounding can inhibit the change of the field of electrostatic induction core wire.

 

The use of 3.2 power filter

 

Power filter is an indispensable component in the anti interference, high frequency and low frequency section has good interference suppression performance. Use should pay attention to matters:

 

A) filter should be installed on the surface of the conductive metal, or woven through the ground and ground;

 

B) location filter should be as close as possible to the power line at the entrance;

 

C) filter input and output the best use of shielded wire or twisted pair;

 

D) to avoid the input and output lines of mutual coupling, the absolute prohibition of the input and output lines bundled with the use of shielded wire.

Recommended Products