.11.848.221.407 G2007Y For Kjellberg Plasma Cutter Machine Nozzle
We can offer you all plasma consumables for , Kjellberg, Esab, Koike, Komatsu, Thermadyne, such as: electrode, nozzle, shield, swirl ring, inner cap, retaining cap, water tube, torch body and so on.
Customer Satisfaction
If you worry about our products’ quality, I can give you some samples to test by free. Please don't hesitate to contact us if you have any questions or concerns before or after your purchase. We are committed to your 100% satisfaction.
Shipping and handing
1. DHL is our preferred shipping method. Meanwhile TNT, EMS, Fedex, UPS are available.
2. Make sure to leave telephone number when filling your buyer information.
3.You can check the goods where it is in transit through tracking NO .
Refund(Echange Only)
1.If you are not satisfied with your purchase, you can echange the items received. you must contact us within 5 days of the receipt
of your order. And you should pay all additional shipping fees incurred and the items returned should be kept in their original
status.
2.If you wish to echange defective or incorrect shipped goods, please contact us within 5 days after receiving the goods.
Notes
1. The buyer are responsible for any insurance you think necessary.
2. The processing time for a specific order varies with the product type and stock status. Mostly, processing time can be 3 to 15 working days.
Machine | HEC NO. | Thum NO. | Ref NO. | Description |
Hifocus 280i Hifocus 360i Hifocus 440i (Carbon Steel) |
K94211 | G901Y | .11.848.201.142 | Cooling tube |
K94212 | G902Y | .11.852.201.142 | Cooling tube | |
K94241 | G931Y | .11.848.401.142 | Cooling tube | |
K0402 | G002Y | .11.848.221.300 | Cathode O2 | |
K0105 | G015Y | .11.848.231.350 | Cathode O2 | |
K0101 | G011Y | .11.848.231.320 | Cathode O2 | |
K0106 | G016Y | .11.848.231.360 | Cathode O2 | |
K0402 | G092Y | .11.848.401.310 | Cathode O2 | |
K7441 | G101 | .11.848.221.145 | Gas guide | |
K1466 | G2006 | .11.848.221.406 | Nozzle O2 25A | |
K1467 | G2007 | .11.848.221.407 | Nozzle O2 35A | |
K54124 | G3004 | .11.848.201.1604 | Nozzle cap | |
K641515 | G4015 | .11.848.201.1515 | Swirl gas cap | |
K641220 | G4020 | .11.848.201.1520 | Swirl gas cap | |
K44191 | G501 | .11.848.201.081 | Protective cap | |
K0403 | G003Y | .11.848.221.310 | Gathode -O2 | |
K7442 | G102 | .11.848.221.146 | Gas guide | |
K1466 | G2006Y | .11.848.221.406 | Nozzle O2 | |
K1467 | G2007Y | .11.848.221.407 | Nozzle O2 | |
K1468 | G2008Y | .11.848.221.408 | Nozzle O2 50A | |
K14610 | G2010Y | .11.848.221.410 | Nozzle O2 80A | |
K14612 | G2012Y | .11.848.221.412 | Nozzle O2 120A | |
K14614 | G2014Y | .11.848.221.414 | Nozzle O2 160A | |
K14616 | G2016Y | .11.848.221.416 | Nozzle O2 200A | |
K14826 | G2326Y | .11.848.221.426 | Nozzle | |
K14830 | G2330Y | .11.848.221.430 | Nozzle | |
K14831 | G2331Y | .11.848.221.431 | Nozzle | |
K11014 | G2514 | .11.848.311.614 | Nozzle | |
K11015 | G2515 | .11.848.311.615 | Nozzle | |
K11016 | G2516 | .11.848.311.616 | Nozzle | |
K11018 | G2518 | .11.848.311.618 | Nozzle | |
K11125 | G2725 | .11.848.411.625 | Nozzle | |
K11127 | G2727 | .11.848.411.627 | Nozzle | |
K11129 | G2729 | .11.848.411.629 | Nozzle | |
K541228 | G3028 | .11.848.201.1628 | Nozzle cap | |
K641522 | G4022 | .11.848.201.1522 | Swirl gas cap | |
K641525 | G4025 | .11.848.201.1525 | Swirl gas cap | |
K641530 | G4030 | .11.848.201.1530 | Swirl gas cap | |
K04242 | G032Y | .11.848.421.310 | Cathode O2 | |
K04244 | G034Y | .11.848.421.330 | Cathode O2 | |
K74251 | G121 | .11.848.421.145 | Gas guide | |
K14826 | G2326Y | .11.848.421.426 | Nozzle O2 280A | |
K14830 | G2330Y | .11.848.421.430 | Nozzle O2 360A | |
K14831 | G2331Y | .11.848.421.431 | Nozzle -O2-400A | |
K541409 | G3209 | .11.848.401.1609 | Nozzle cap | |
K541419 | G3219 | .11.848.401.1619 | Nozzle cap | |
K541429 | G3229 | .11.848.401.1629 | Nozzle cap | |
K641745 | G4345 | .11.848.401.1545 | Swirl gas cap | |
K641750 | G4350 | .11.848.401.1550 | Swirl gas cap | |
K641755 | G4355 | .11.848.401.1555 | Swirl gas cap | |
K44201 | G521 | .11.848.401.081 | Protective cap | |
K94211 | G901Y | .11.848.201.142 | Water Tube | |
K94212 | G902Y | .11.852.201.142 | Water Tube | |
K94241 | G931Y | .11.848.401.142 | Water Tube |
Technical Support:
Anti interference wiring measures for machine tools
CNC device and servo unit of NC plasma arc cutting system is the core part of the system, the power supply is the main way to enter the interference. The interference of power supply is mainly produced by the impedance coupling power supply line, all kinds of high-power electric equipment is the main source of interference.
3.1 power supply into line with shielded wire
Power line NC plasma arc cutting system. Cathode line of the cutting torch and plasma / arc arc line hanging in the sliding support, equivalent to go parallel lines tens of meters and / arc line control, torch cathode line from the plasma power, torch cathode of the DC line current 100 amperes. It produces electromagnetic field and high frequency lead arc of high frequency signal by coupling the will power of CNC device and servo unit caused by electromagnetic interference.
With copper and aluminum for shielding cable shielding layer can effectively suppress the interference of high frequency electromagnetic shielding, grounding can inhibit the change of the field of electrostatic induction core wire.
The use of 3.2 power filter
Power filter is an indispensable component in the anti interference, high frequency and low frequency section has good interference suppression performance. Use should pay attention to matters:
A) filter should be installed on the surface of the conductive metal, or woven through the ground and ground;
B) location filter should be as close as possible to the power line at the entrance;
C) filter input and output the best use of shielded wire or twisted pair;
D) to avoid the input and output lines of mutual coupling, the absolute prohibition of the input and output lines bundled with the use of shielded wire.